IEC-61850 Gateways

IEC-60870-5(IEC101,IEC102,IEC103,IEC104) to IEC-61850 Gateway

IEC101/102/103/104 to IEC61850 or Modbus Gateway

BUE-61850 series IEC-61850 Gateways can provides both industrial communication device and solution of the whole industrial automation system,which plays more important roles in industrial control and automation,especially in the substation automation.

1.Communication function:

Protocol conversion:

Standard protocols that BUE-61850 support: UCA2,OPC,TCP/IP, Serial, DNP3,OPC, Modbus RTU/TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104), IEC61850(Our IEC61850 Can work as server or client)

Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-61850


Data processing:

Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.

Point table custom and information split:

In the BUE-61850 system it provides different data forwarding point tables,different channels’ protocol  can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.


Dual channel processing:

BUE-61850 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.


Measuring point self description:

BUE-61850 supports self description of data point, which is convenient for maintenance and debugging.


2.Advanced application:

Data calculation:

BUE-61850 provides standard calculation formula and take the processing of data in the way of  addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.

Equipment automatic control can be set up:


BUE-61850 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.

Advanced equipment control integration

3.Management function:

Debugging management:

BUE-61850 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.

Equipment management:

Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.

Time synchronization:

BUE-61850 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.

4.System feature:

Low latency: 5 to 50ms latency.

Strong data processing ability.

Reliable communication management


5. Technical specifications:
Hardware:
10/100MTCP/IP:  2-6 nos
RS422/232/485    4-16 nos
DI/DO   8 nos
LED lights:  8nos
Wireless(GPRS/Zigbee/wifi/BD)  1 nos

Software:
Maximum channels:200
Maximum digital number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel:   65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)

Technical specs

400Mhz Freescale MPC8308 CPU

128M DDR2 Memory

128M Nand Flash

2 Ethernet Ports

4 RS-232/485 Isolation Serial Ports

DIN-Rail Mount

System

CPU

Freescale MPC8308 PowerPC CPU,400MHz

Memory

DDR2 128M

Flash

8M Nor Flash

128M Nand Flash

Operating System

Linux 2.6.29.6

LED

 

System:Power x1,RUN x1,

LAN:10/100/1000M x4(Link x2 Act x2)

Serial:TxD x4,RxD x4

Others

RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1

Serial Communication

Console Port

Console Port RJ45 connector x1

RS232 115200bps N,8,1

Serial Port

4 xRS-232/485 TB Interface connector

software-selectable

RS-232 Signals:TxD,RxD,GND

RS-485 Signals:485A(Data+),485B(Data-)

Protection

Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection

Network Communication

LAN

Auto-sensing 10/100/1000Mbps x 2, RJ45

Build-in 1.5KV magnetic isolation protection

Power Requirements

Power Input

Dual Power Input Design

PWR1:9-48VDC or 9-48VAC

PWR2:9-48VDC or 9-48VAC

Lost power alarm

Relay empty node

Power Consumption

 

 

8W@12VDC

Mechanical

Dimensions

200(L)x121.01(W)x54.1(H)

Installation

DIN-Rail Mount

Environmental

Operating Temperature

-20-60℃

Storage Temperature

-30-80℃

Regulatory Approvals and Warranty

EMC

GB/T 17626.2-2006 Class 4

GB/T 17626.4-2008 Class 4

GB/T 17626.5-2008 Class 4

GB/T 17626.6-2008 Class 3

Warranty

5 Years