1.Communication function:
Protocol conversion:
Standard protocols that BUE-801 support: UCA2,OPC,TCP/IP, Serial, DNP3,OPC, Modbus RTU/TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104), IEC61850(Our IEC61850 Can work as server or client)
Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-801
Data processing:
Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.
Point table custom and information split:
In the BUE-801 system it provides different data forwarding point tables,different channels’ protocol can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.
Dual channel processing:
BUE-801 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.
Measuring point self description:
BUE-801 supports self description of data point, which is convenient for maintenance and debugging.
2.Advanced application:
Data calculation:
BUE-801 provides standard calculation formula and take the processing of data in the way of addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.
Equipment automatic control can be set up:
BUE-801 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.
Advanced equipment control integration
3.Management function:
Debugging management:
BUE-801 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.
Equipment management:
Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.
Time synchronization:
BUE-801 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.
4.System feature:
Low latency: 5 to 50ms latency.
Strong data processing ability.
Reliable communication management
5. Technical specifications:
Hardware:
10/100MTCP/IP: 2-6 nos
RS422/232/485 4-16 nos
DI/DO 8 nos
LED lights: 8nos
Wireless(GPRS/Zigbee/wifi/BD) 1 nos
Software:
Maximum channels:200
Maximum digital number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel: 65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)
Technical specs:
400Mhz Freescale MPC8308 CPU
128M DDR2 Memory
128M Nand Flash
2 Ethernet Ports
4 RS-232/485 Isolation Serial Ports
DIN-Rail Mount
|
System |
|
|
CPU |
Freescale MPC8308 PowerPC CPU,400MHz |
|
Memory |
DDR2 128M |
|
Flash |
8M Nor Flash |
|
128M Nand Flash |
|
|
Operating System |
Linux 2.6.29.6 |
|
LED |
|
|
|
System:Power x1,RUN x1, LAN:10/100/1000M x4(Link x2 Act x2) Serial:TxD x4,RxD x4 |
|
Others |
RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1 |
|
Serial Communication |
|
|
Console Port |
Console Port RJ45 connector x1 RS232 115200bps N,8,1 |
|
Serial Port |
4 xRS-232/485 TB Interface connector software-selectable RS-232 Signals:TxD,RxD,GND RS-485 Signals:485A(Data+),485B(Data-) |
|
Protection |
Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection |
|
Network Communication |
|
|
LAN |
Auto-sensing 10/100/1000Mbps x 2, RJ45 Build-in 1.5KV magnetic isolation protection |
|
Power Requirements |
|
|
Power Input |
Dual Power Input Design PWR1:9-48VDC or 9-48VAC PWR2:9-48VDC or 9-48VAC |
|
Lost power alarm |
Relay empty node |
|
Power Consumption |
|
|
|
8W@12VDC |
|
Mechanical |
|
|
Dimensions |
200(L)x121.01(W)x54.1(H) |
|
Installation |
DIN-Rail Mount |
|
Environmental |
|
|
Operating Temperature |
-20-60℃ |
|
Storage Temperature |
-30-80℃ |
|
Regulatory Approvals and Warranty |
|
|
EMC |
GB/T 17626.2-2006 Class 4 GB/T 17626.4-2008 Class 4 GB/T 17626.5-2008 Class 4 GB/T 17626.6-2008 Class 3 |
|
Warranty |
5 Years |
BUE-801 series IEC-60870 Gateways can provides both industrial communication device and solution of the whole industrial automation system,which plays more important roles in industrial control and automation,especially in the substation automation.The IEC-60870 sub protocols can communicate with each other,eg. The BUE-801 supports IEC101 to IEC102,IEC101 to IEC103,IEC101 to IEC104,IEC102 to IEC103,IEC102 to IEC104,IEC103 to IEC104, IEC101 to Modbus RTU/TCP,IEC102 to Modbus RTU/TCP,IEC103 to Modbus RTU/TCP, IEC104 to Modbus RTU/TCP and IEC101/102/103/104 to IEC61850 and other substation communication protocols.
1.Communication function:
Protocol conversion:
Standard protocols that BUE-801 support: UCA2,OPC,TCP/IP, Serial, DNP3,OPC, Modbus RTU/TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104), IEC61850(Our IEC61850 Can work as server or client)
Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-801
Data processing:
Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.
Point table custom and information split:
In the BUE-801 system it provides different data forwarding point tables,different channels’ protocol can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.
Dual channel processing:
BUE-801 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.
Measuring point self description:
BUE-801 supports self description of data point, which is convenient for maintenance and debugging.

2.Advanced application:
Data calculation:
BUE-801 provides standard calculation formula and take the processing of data in the way of addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.
Equipment automatic control can be set up:
BUE-801 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.
Advanced equipment control integration
3.Management function:
Debugging management:
BUE-801 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.
Equipment management:
Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.
Time synchronization:
BUE-801 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.
4.System feature:
Low latency: 5 to 50ms latency.
Strong data processing ability.
Reliable communication management
5. Technical specifications:
Hardware:
10/100MTCP/IP: 2-6 nos
RS422/232/485 4-16 nos
DI/DO 8 nos
LED lights: 8nos
Wireless(GPRS/Zigbee/wifi/BD) 1 nos
Software:
Maximum channels:200
Maximum digital number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel: 65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)
Technical specs:
400Mhz Freescale MPC8308 CPU
128M DDR2 Memory
128M Nand Flash
2 Ethernet Ports
4 RS-232/485 Isolation Serial Ports
DIN-Rail Mount
|
System |
|
|
CPU |
Freescale MPC8308 PowerPC CPU,400MHz |
|
Memory |
DDR2 128M |
|
Flash |
8M Nor Flash |
|
128M Nand Flash |
|
|
Operating System |
Linux 2.6.29.6 |
|
LED |
|
|
|
System:Power x1,RUN x1, LAN:10/100/1000M x4(Link x2 Act x2) Serial:TxD x4,RxD x4 |
|
Others |
RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1 |
|
Serial Communication |
|
|
Console Port |
Console Port RJ45 connector x1 RS232 115200bps N,8,1 |
|
Serial Port |
4 xRS-232/485 TB Interface connector software-selectable RS-232 Signals:TxD,RxD,GND RS-485 Signals:485A(Data+),485B(Data-) |
|
Protection |
Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection |
|
Network Communication |
|
|
LAN |
Auto-sensing 10/100/1000Mbps x 2, RJ45 Build-in 1.5KV magnetic isolation protection |
|
Power Requirements |
|
|
Power Input |
Dual Power Input Design PWR1:9-48VDC or 9-48VAC PWR2:9-48VDC or 9-48VAC |
|
Lost power alarm |
Relay empty node |
|
Power Consumption |
|
|
|
8W@12VDC |
|
Mechanical |
|
|
Dimensions |
200(L)x121.01(W)x54.1(H) |
|
Installation |
DIN-Rail Mount |
|
Environmental |
|
|
Operating Temperature |
-20-60℃ |
|
Storage Temperature |
-30-80℃ |
|
Regulatory Approvals and Warranty |
|
|
EMC |
GB/T 17626.2-2006 Class 4 GB/T 17626.4-2008 Class 4 GB/T 17626.5-2008 Class 4 GB/T 17626.6-2008 Class 3 |
|
Warranty |
5 Years |
BUE-801 series IEC-60870 to Modbus Gateways can provides both industrial communication device and solution of the whole industrial automation system,which plays more important roles in industrial control and automation,especially in the substation automation.
1.Communication function:
Protocol conversion:
Standard protocols that BUE-801 support: UCA2,TCP/IP, Serial, DNP3,OPC, Modbus RTU/TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104),or IEC61850. All the protocols can communicate with any one protocol in our protocol list.
Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-801
Data processing:
Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.
Point table custom and information split:
In the system it provides different data forwarding point tables,different channels’ protocol can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.
Dual channel processing:
BUE-801 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.
Measuring point self description:
BUE-801 supports self description of data point, which is convenient for maintenance and debugging.
2.Advanced application:
Data calculation:
BUE-801 provides standard calculation formula and take the processing of data in the way of addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.
Equipment automatic control can be set up:
BUE-801 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.
Advanced equipment control integration
3.Management function:
Debugging management:
BUE-801 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.
Equipment management:
Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.
Time synchronization:
BUE-801 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.
4.System feature:
Low lantency: 5 to 50ms lantency.
Strong data processing ability.
Reliable communication management
5. Technical specifications:
Hardware:
10/100MTCP/IP: 2-6 nos
RS422/232/485 4-16 nos
DI/DO 8 nos
LED lights: 8nos
Wireless(GPRS/Zigbee/wifi/BD) 1 nos
Software:
Maximum channels:200
Maximum digital number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel: 65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)
Technical specs:
400Mhz Freescale MPC8308 CPU
128M DDR2 Memory
128M Nand Flash
2 Ethernet Ports
4 RS-232/485 Isolation Serial Ports
DIN-Rail Mount
|
System |
|
|
CPU |
Freescale MPC8308 PowerPC CPU,400MHz |
|
Memory |
DDR2 128M |
|
Flash |
8M Nor Flash |
|
128M Nand Flash |
|
|
Operating System |
Linux 2.6.29.6 |
|
LED |
|
|
|
System:Power x1,RUN x1, LAN:10/100/1000M x4(Link x2 Act x2) Serial:TxD x4,RxD x4 |
|
Others |
RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1 |
|
Serial Communication |
|
|
Console Port |
Console Port RJ45 connector x1 RS232 115200bps N,8,1 |
|
Serial Port |
4 xRS-232/485 TB Interface connector software-selectable RS-232 Signals:TxD,RxD,GND RS-485 Signals:485A(Data+),485B(Data-) |
|
Protection |
Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection |
|
Network Communication |
|
|
LAN |
Auto-sensing 10/100/1000Mbps x 2, RJ45 Build-in 1.5KV magnetic isolation protection |
|
Power Requirements |
|
|
Power Input |
Dual Power Input Design PWR1:9-48VDC or 9-48VAC PWR2:9-48VDC or 9-48VAC |
|
Lost power alarm |
Relay empty node |
|
Power Consumption |
|
|
|
8W@12VDC |
|
Mechanical |
|
|
Dimensions |
200(L)x121.01(W)x54.1(H) |
|
Installation |
DIN-Rail Mount |
|
Environmental |
|
|
Operating Temperature |
-20-60℃ |
|
Storage Temperature |
-30-80℃ |
|
Regulatory Approvals and Warranty |
|
|
EMC |
GB/T 17626.2-2006 Class 4 GB/T 17626.4-2008 Class 4 GB/T 17626.5-2008 Class 4 GB/T 17626.6-2008 Class 3 |
|
Warranty |
5 Years |
BUE-61850 series IEC-61850 Gateways can provides both industrial communication device and solution of the whole industrial automation system,which plays more important roles in industrial control and automation,especially in the substation automation.
1.Communication function:
Protocol conversion:
Standard protocols that BUE-61850 support: UCA2,OPC,TCP/IP, Serial, DNP3,OPC, Modbus RTU/TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104), IEC61850(Our IEC61850 Can work as server or client)
Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-61850
Data processing:
Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.
Point table custom and information split:
In the BUE-61850 system it provides different data forwarding point tables,different channels’ protocol can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.
Dual channel processing:
BUE-61850 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.
Measuring point self description:
BUE-61850 supports self description of data point, which is convenient for maintenance and debugging.

2.Advanced application:
Data calculation:
BUE-61850 provides standard calculation formula and take the processing of data in the way of addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.
Equipment automatic control can be set up:
BUE-61850 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.
Advanced equipment control integration
3.Management function:
Debugging management:
BUE-61850 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.
Equipment management:
Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.
Time synchronization:
BUE-61850 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.
4.System feature:
Low latency: 5 to 50ms latency.
Strong data processing ability.
Reliable communication management
5. Technical specifications:
Hardware:
10/100MTCP/IP: 2-6 nos
RS422/232/485 4-16 nos
DI/DO 8 nos
LED lights: 8nos
Wireless(GPRS/Zigbee/wifi/BD) 1 nos
Software:
Maximum channels:200
Maximum digital number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel: 65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)
Technical specs:
400Mhz Freescale MPC8308 CPU
128M DDR2 Memory
128M Nand Flash
2 Ethernet Ports
4 RS-232/485 Isolation Serial Ports
DIN-Rail Mount
|
System |
|
|
CPU |
Freescale MPC8308 PowerPC CPU,400MHz |
|
Memory |
DDR2 128M |
|
Flash |
8M Nor Flash |
|
128M Nand Flash |
|
|
Operating System |
Linux 2.6.29.6 |
|
LED |
|
|
|
System:Power x1,RUN x1, LAN:10/100/1000M x4(Link x2 Act x2) Serial:TxD x4,RxD x4 |
|
Others |
RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1 |
|
Serial Communication |
|
|
Console Port |
Console Port RJ45 connector x1 RS232 115200bps N,8,1 |
|
Serial Port |
4 xRS-232/485 TB Interface connector software-selectable RS-232 Signals:TxD,RxD,GND RS-485 Signals:485A(Data+),485B(Data-) |
|
Protection |
Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection |
|
Network Communication |
|
|
LAN |
Auto-sensing 10/100/1000Mbps x 2, RJ45 Build-in 1.5KV magnetic isolation protection |
|
Power Requirements |
|
|
Power Input |
Dual Power Input Design PWR1:9-48VDC or 9-48VAC PWR2:9-48VDC or 9-48VAC |
|
Lost power alarm |
Relay empty node |
|
Power Consumption |
|
|
|
8W@12VDC |
|
Mechanical |
|
|
Dimensions |
200(L)x121.01(W)x54.1(H) |
|
Installation |
DIN-Rail Mount |
|
Environmental |
|
|
Operating Temperature |
-20-60℃ |
|
Storage Temperature |
-30-80℃ |
|
Regulatory Approvals and Warranty |
|
|
EMC |
GB/T 17626.2-2006 Class 4 GB/T 17626.4-2008 Class 4 GB/T 17626.5-2008 Class 4 GB/T 17626.6-2008 Class 3 |
|
Warranty |
5 Years |
BUE-61850 series IEC-61850 Gateways can provides both industrial communication device and solution of the whole industrial automation system,which plays more important roles in industrial control and automation,especially in the substation automation.
1.Communication function:
Protocol conversion:
Standard protocols that BUE-61850 support: UCA2,CDT,DLT645,TCP/IP, DNP3, OPC, Modbus RTU,Modbus TCP, IEC60870-5 series(IEC101,IEC102,IEC103,IEC104), IEC61850(Our IEC61850 Can work as server or client)
Non-standard protocol: DC screen,power meter,safety equipments.The different protocols of data can convert with each other in the BUE-61850
Data processing:
Digital processing: signal acquisition & transmission,anti-shake,singnal maintenance, timing alarm, quality judgment.
Analog processing: multiplication coefficient, residual cleared, anti-mutation, quality judgment,etc.
Point table custom and information split:
In the BUE-61850 system it provides different data forwarding point tables,different channels’ protocol can forward and each uses different data forwarding table. The same data can be submitted to the upper machine in the form of different value.
Dual channel processing:
BUE-61850 Supports the system with dual channel mode and the upper machine communication, including fully redundant dual channel way, communication link redundancy, main equipment and so on.
Measuring point self description:
BUE-61850 supports self description of data point, which is convenient for maintenance and debugging.

2.Advanced application:
Data calculation:
BUE-61850 provides standard calculation formula and take the processing of data in the way of addition, subtraction, multiplication, division, logic judgment (including greater than, less than, equal to, is not equal to, greater than or equal to, less than or equal to, logic and logic, logic or, not), sine, cosine, square root, take maximum, minimum, average calculation.
Equipment automatic control can be set up:
BUE-61850 provides the setting of basic control logic, timing or logical calculation according to the real-time data of on-site equipment start-stop switch quantity control and analog control, such as temperature, pressure, etc.
Advanced equipment control integration
3.Management function:
Debugging management:
BUE-61850 provides all kinds of debugging methods and management, including remote debugging, intelligent device simulation, data simulation, control block, data browsing, message and debugging information monitoring, message storage and playback, flow rate and bit error rate statistics.
Equipment management:
Equipment management functions includes: remote diagnosis and maintenance, hardware watchdog, custom information indicator, main standby switch management etc.
Time synchronization:
BUE-61850 can receive the time code from time servers,it can synchronizes time in the format of IRIG-B and NTP/SNTP.
4.System feature:
Low latency: 5 to 50ms latency.
Strong data processing ability.
Reliable communication management
5. Technical specifications:
Hardware:
10/100MTCP/IP: 2-6 nos
RS422/232/485 4-16 nos
DI/DO 8 nos
LED lights: 8nos
Wireless(GPRS/Zigbee/wifi/BD) 1 nos
Software:
Maximum channels:200
Maximum digital output number/channel: 65536
Maximum analog number/channel: 65536
Maximum electric degree/channel: 65536
Maximum output/channel: 65536
Maximum analog output/channel: 65536
Data forwarding base: 4
Minimum data processing lantency: 5ms
Time synchronization precision:<1ms(Hardware synchronization)
Technical specs:
400Mhz Freescale MPC8308 CPU
128M DDR2 Memory
128M Nand Flash
2 Ethernet Ports
4 RS-232/485 Isolation Serial Ports
DIN-Rail Mount
|
System |
|
|
CPU |
Freescale MPC8308 PowerPC CPU,400MHz |
|
Memory |
DDR2 128M |
|
Flash |
8M Nor Flash |
|
128M Nand Flash |
|
|
Operating System |
Linux 2.6.29.6 |
|
LED |
|
|
|
System:Power x1,RUN x1, LAN:10/100/1000M x4(Link x2 Act x2) Serial:TxD x4,RxD x4 |
|
Others |
RTC,Buzzer,Watchdog Timer,Reset button,Console Port x1 |
|
Serial Communication |
|
|
Console Port |
Console Port RJ45 connector x1 RS232 115200bps N,8,1 |
|
Serial Port |
4 xRS-232/485 TB Interface connector software-selectable RS-232 Signals:TxD,RxD,GND RS-485 Signals:485A(Data+),485B(Data-) |
|
Protection |
Built-in 15KV ESD protection for all signals, 2KV iCoupler digital isolation protection |
|
Network Communication |
|
|
LAN |
Auto-sensing 10/100/1000Mbps x 2, RJ45 Build-in 1.5KV magnetic isolation protection |
|
Power Requirements |
|
|
Power Input |
Dual Power Input Design PWR1:9-48VDC or 9-48VAC PWR2:9-48VDC or 9-48VAC |
|
Lost power alarm |
Relay empty node |
|
Power Consumption |
|
|
|
8W@12VDC |
|
Mechanical |
|
|
Dimensions |
200(L)x121.01(W)x54.1(H) |
|
Installation |
DIN-Rail Mount |
|
Environmental |
|
|
Operating Temperature |
-20-60℃ |
|
Storage Temperature |
-30-80℃ |
|
Regulatory Approvals and Warranty |
|
|
EMC |
GB/T 17626.2-2006 Class 4 GB/T 17626.4-2008 Class 4 GB/T 17626.5-2008 Class 4 GB/T 17626.6-2008 Class 3 |
|
Warranty |
5 Years |
HFB IEC 61850-3 Ethernet switches are designed specifically for substation environments. The entire line of PowerTrans series has passed IEC 61850-3 and IEEE 1613 (conducted by KEMA) for GOOSE compliance and zero packet loss performance. The series also supports IEEE 1588 protocol for timing accuracy over substation LAN, which is highly favorable for large-scale distributed power grids.
* IEC 61850-3, IEEE1613 (power substations),
* Smart web-based management makes configuration easy
* Port-based VLAN to enhance security/network performance and ease network planning
* 802.1p priority queues and port-based QoS to increase determinism
* -40 to 85°C operating temperature range
Introduction
The HFB6128 is designed to meet the demands of power substation automation systems (IEC 61850-3, IEEE 1613), and railway applications (EN50155/EN50121-4). The MX6000’s Gigabit and fast Ethernet backbone, redundant ring, and 48 VDC or 110/220
VDC/VAC dual isolated redundant power supplies increase the reliability of your communications and save on cabling/wiring costs.
The switches design of the MX6000 also makes network planning easy, and allows greater flexibility by letting you install up to 12 fast fiber ports and 20 fast Ethernet ports.
Features and Benefits
• RingOn (recovery time < 15 ms), RSTP/STP for network redundancy
• IGMP snooping for filtering multicast traffic
• Port-based VLAN, IEEE 802.1Q VLAN to ease network planning
• QoS (IEEE 802.1p/1Q) and TOS/DiffServ to increase determinism
• Port Trunking for optimum bandwidth utilization
• RMON for efficient network monitoring and proactive capability
• SNMP v1/v2c/v3 for network management of different levels
• Bandwidth management to prevent unpredictable network status
• Lock port function for blocking unauthorized access based on MAC address
• Automatic warning by exception through e-mail or relay output
• Port mirroring for online debugging
• -40 to 85°C operating temperature range (W models)
Cyber-security Features
• User passwords with multiple levels of security protect against unauthorized configuration
• 802.1Q VLAN allows you to logically partition traffic transmitted between selected switch ports
• Secure switch ports so that only specific devices and/or MAC addresses can access the ports
• SNMP v3 provides encrypted authentication and access security
Technology
Standards:
IEEE802.3 10Base-T
IEEE802.3u 100BaseT(X) and 100BaseFX IEEE802.3x Flow Control
IEEE802.1p Classe of Service
IEEE802.1Q VLAN Tagging
IEEE802.1D for Spanning Tree Protocol
IEEE802.1W for Rapid STP IEEE802.1X for Authentication
Flow Control: Full/Half Duplex Back Pressure Flow Control Protocols: SNMP V1/V2c/V3, DHCP Server, SNTP, SMTP, IGMP Snooping, RMON, HTTPS,
Telnet, Syslog, HTTP
Switch Properties
Priority Queues: 4
IGMP Groups: 256
Max. Available VLANs: 64
VLAN ID Range: 1~4094
Interface
RJ45 Port Connectors: 10/100Base Auto-sensing, Full/ Half Duplex MDI/MDI-X Auto-Negotiation
Fiber Port Connectors: 100BaseFX, SC or ST
connectors, Single-Mode or Multi-Mode
LED Indicators: Power, Port Status, 10/100M Console Port: DB9 male
Power Requirements
Power Inputs:
200~350VDC @ 20W MAX; 165~265VAC @ 20VA MAX Optical Fiber
100BaseFX
Typical Dist:
Multi-mode: 2km, 1310nm(62.5/125μm) Single-mode: 15km, 1310nm(9/125μm) Min. TX:
Multi-mode: -23.5dBm Single-mode: -15dBm Max. TX:
Multi-mode: -14dBm
Single-mode: -8dBm
RX Sensitivity: <-35dBm(Multi/Single) Physical Characteristics
Case: Slim Metal Case, IP40 Design Dimensions: (W×H×D): 443×44×237.8mm Installation: 19” rack mounting
Environment Limits
Extended Temp Models: -40˚C to 85˚C Storage Temperature: -40 to 85˚C
Ambient Relative Humidity: 10 to 95%(Non-condensing) Agency Approvals
Power Automation: IEC 61850-3, IEEE 1613
EMI:FCC Part15, CISPR(EN55022) Class A
EMC:
EN61000-4-2(ESD), Lv4
EN61000-4-3(RS), Lv4
EN61000-4-4(EFT), Lv4
EN61000-4-5(Surge), Lv4
EN61000-4-6(CS), Lv4
EN61000-4-8
EN61000-4-11
Warranty
Warranty Period: 5 years
|
KEMA Standard |
|
|
|
|
|
|
Model |
Port |
100M |
SC Fiber |
Gigabit |
Work Temperature |
|
HFB6128-24T |
24 |
24 |
|
|
-40 -- +85 |
|
HFB6128-20T4MC |
24 |
20 |
4 |
|
-40 -- +85 |
|
HFB6128-16T8MC |
24 |
16 |
8 |
|
-40 -- +85 |
|
HFB6128-12T12MC |
24 |
12 |
12 |
|
-40 -- +85 |
|
HFB6128-8T16MC |
24 |
8 |
16 |
|
-40 -- +85 |
|
HFB6128-4T20MC |
24 |
4 |
20 |
|
-40 -- +85 |
|
HFB6128-24MC |
24 |
|
24 |
|
-40 -- +85 |
|
HFB6128-24T-4G |
28 |
24 |
|
4 |
-40 -- +85 |
|
HFB6128-20T4MC-4G |
28 |
20 |
4 |
4 |
-40 -- +85 |
|
HFB6128-16T8MC-4G |
28 |
16 |
8 |
4 |
-40 -- +85 |
|
HFB6128-12T12MC-4G |
28 |
12 |
12 |
4 |
-40 -- +85 |
|
HFB6128-8T16MC-4G |
28 |
8 |
16 |
4 |
-40 -- +85 |
|
HFB6128-4T20MC-4G |
28 |
4 |
20 |
4 |
-40 -- +85 |
|
HFB6128-24MC-4G |
28 |
|
24 |
4 |
-40 -- +85 |