Overview
The SED 4-port device servers(EMC-4 Grade) are designed to make serial devices network-ready in an instant and give your PC software direct access to serial devices from anywhere on the network. The SED device servers are ultra lean, ruggedized, and user friendly, making simple and reliable serial to Ethernet solutions possible.The product can be used in harsh environment.
Features and Benefits
· World’s lowest power consumption
· Speedy 3-step web-based configuration
· Surge protection for serial, Ethernet, and power lines
· COM port grouping and UDP multicast applications
· Screw connectors for secure installation
· DC power inputs with terminal block
· Versatile TCP and UDP operation modes
A Greener Serial-to-Ethernet Solution
The is a small but powerful ARM-based serial-to-Ethernet SoC with RAM and Flash embedded. With the ARM9 inside, the SED series becomes the lowest power consumption device server in the world. The SED series saves at least 50% on power consumption compared to existing solutions on the market, helping engineers meet the tough environmental compliance challenges found in today’s industrial environments.
3-step Web-based Configuration
The SEDs 3-step web-based configuration tool is straightforward and user-friendly. The SED’s web console guides users through 3 simple configuration steps that are necessary to activate the serial-to-Ethernet application. With this speedy 3-step web-based configuration, a user only needs to spend an average of 30 seconds to complete the settings and enable the application, saving a great amount of time and effort.
COM Port Grouping
The SED COM Grouping function allows you to create a COM Group and redirect data from it to several physical COM ports on device servers. With COM Grouping, you will be able to control multiple physical serial ports simultaneously by operating only one COM port.
The SED series can conveniently connect up to 4 serial devices to an Ethernet, allowing you to network your existing serial devices with only basic configuration. With SED series, you can both centralize the management of your serial devices, and distribute management hosts over the network. SED series can be used to connect different devices for remote management, each serial port operates independently to provide maximum versatility, each port can be operate in Driver, TCP Server, and TCP Client mode independently.
Features:
1. Adopt 32 bit ARM processor
2. 4 serial ports, with support for RS-232/RS-485/RS-422
3. Support 10/100M Ethernet
4. Support 300bps-460.8Kbps
5. Support ICMP,IP,TCP,UDP,DHCP,BOOTP,Telnet,DNS,SNMP V1,HTTP,SMTP,SNTP,ARP,PPP,SLIP
6. Support across gateway, router communication
7. Support standard TCP/IP SOCKET
8. Support Virtual serial driver access and auto connect after the network disconnect
9. Choice of configuration methods: Windows, TELNET and WEB
10. Support DIN-Rail or wall mounting installation
Specifications:
Ethernet
Number of ports:1
Standard:10/100Base-T(X)
Speed:10/100M auto-sensing
Working mode: half /full duplex
Working: TCP Server, TCP Client, UDP and Real COM driver
Memory: 8M RAM,4M flash
Electromagnetism isolate: 1.5KV
Connector: RJ45
Serial
Standard:RS-232/RS-485/RS-422
Number of ports: 4
Signals: RS-232:DCD,RXD,TXD,DTR,GND,DSR,RTS,CTS
RS-485:Data+,Data-,GND
RS-422:TXD+,TXD-,RXD+,RXD-,GND
Parity: None, Even, Odd, Space, Mark
Data bits: 5bit, 6bit, 7bit, 8bit
Stop bits: 1, 1.5, 2
Baud rate: 300bps ~ 460.8Kbps
Flow control: RTS/CTS or XON/XOFF
Direction control: RS485 side adopt ADDC technology, auto text and control data transfer direction
Loading: RS-485/422 side support 32 nodes (customize 128 nodes) loopback
Transmission: RS-485/422 side 1200M,
RS-232 port 15M
Interface protection:600W surge protection,
15KV ESD protection
12KV Isolation
Software
Network protocols: Support ICMP,IP,TCP,UDP,DHCP,BOOTP,Telnet,DNS,SNMP V1,HTTP,SMTP,SNTP,ARP,PPP,SLIP
Driver support: Windows Real COM driver(Windows NT/2000, Windows XP/2003)
Configuration options: Windows, TELNET and WEB
Power
Power input: 9-40VDC
Consumption: <2.5W
Environment
Working temperature:-20°C~60°C
Storage temperature:-25°C~85°C
Humidity: Relative humidity 5% to 95%
Appearance
Color: Black
163*102.5*27(L*W*H)
Material: Iron (Shell)
Ordering Information:
SED4-A:rs232 mode
SED4-B:rs485 or rs422 mode
SED4-C:rs232,rs422,rs485 3 in 1
The connection way may combine willfully ,serial connector can be termial mark or RJ45 conncetor.
Safety: EN 60950-1
EMC: CE, FCC
GB/T 17626.2-2006 Class 4
GB/T 17626.4-2008 Class 4
GB/T 17626.5-2008 Class 4
GB/T 17626.6-2008 Class 3
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 55024
Power Line Protection:
EN 61000-4-4(EFT) Level 2,
EN 61000-4-5(Surge) Level 3
Warranty: 5 Years
Overview
The SED2 device servers are designed to make serial devices network-ready in an instant and give your PC software direct access to serial devices from anywhere on the network. The SED2 device servers are ultra lean, ruggedized, and user friendly, making simple and reliable serial to Ethernet solutions possible.The SED2 passed EMC-4 testing and it can be used in harsh environments.
Features and Benefits
· Speedy 3-step web-based configuration
· Surge protection for serial, Ethernet, and power lines
· COM port grouping and UDP multicast applications
· Screw connectors for secure installation
· DC power inputs with terminal block
· Versatile TCP and UDP operation modes
A Greener Serial-to-Ethernet Solution
The SED2 is a small but powerful ARM-based serial-to-Ethernet SoC with RAM and Flash embedded. With the ARM7 inside, the SED2 series becomes the lowest power consumption device server in the world. The SED2 series saves at least 50% on power consumption compared to existing solutions on the market, helping engineers meet the tough environmental compliance challenges found in today’s industrial environments.
3-step Web-based Configuration
The SED2’s 3-step web-based configuration tool is straightforward and user-friendly. The SED2’s web console guides users through 3 simple configuration steps that are necessary to activate the serial-to-Ethernet application. With this speedy 3-step web-based configuration, a user only needs to spend an average of 30 seconds to complete the settings and enable the application, saving a great amount of time and effort.
COM Port Grouping
The SED2’s COM Grouping function allows you to create a COM Group and redirect data from it to several physical COM ports on device servers. With COM Grouping, you will be able to control multiple physical serial ports simultaneously by operating only one COM port.
The SED2 series can conveniently connect up to 2 serial devices to an Ethernet, allowing you to network your existing serial devices with only basic configuration. With SED2 series, you can both centralize the management of your serial devices, and distribute management hosts over the network. SED2 series can be used to connect different devices for remote management, each serial port operates independently to provide maximum versatility, each port can be operate in Driver, TCP Server, and TCP Client mode independently.
Features:
1. Adopt 32 bit ARM processor
2. 2 serial ports, with support for RS-232/RS-485/RS-422
3. Support 10/100M Ethernet
4. Support 300bps-460.8Kbps
5. Support ICMP,IP,TCP,UDP,DHCP,BOOTP,Telnet,DNS,SNMP V1,HTTP,SMTP,SNTP,ARP,PPP,SLIP
6. Support across gateway, router communication
7. Support standard TCP/IP SOCKET
8. Support Virtual serial driver access and auto connect after the network disconnect
9. Choice of configuration methods: Windows, TELNET and WEB
10. Support DIN-Rail or wall mounting installation
Specifications:
Ethernet
Number of ports:1
Standard:10/100Base-T(X)
Speed:10/100M auto-sensing
Working mode: half /full duplex
Working: TCP Server, TCP Client, UDP and Real COM driver
Memory: 128KB RAM,512K flash
Electromagnetism isolate: 12KV
SPD: 600W
ESD:15KV
Connector: RJ45
Serial
Standard:RS-232/RS-485/RS-422
Number of ports: 2
Signals: RS-232:DCD,RXD,TXD,DTR,GND,DSR,RTS,CTS
RS-485:Data+,Data-,GND
RS-422:TXD+,TXD-,RXD+,RXD-,GND
Parity: None, Even, Odd, Space, Mark
Data bits: 5bit, 6bit, 7bit, 8bit
Stop bits: 1, 1.5, 2
Baud rate: 300bps ~ 460.8Kbps
Flow control: RTS/CTS or XON/XOFF
Direction control: RS485 side adopt ADDC technology, auto text and control data transfer direction
Loading: RS-485/422 side support 32 nodes (customize 128 nodes) loopback
Transmission: RS-485/422 side 1200M,
RS-232 port 15M
Interface protection:600W surge protection,
15KV ESD protection
Software
Network protocols: Support ICMP,IP,TCP,UDP,DHCP,BOOTP,Telnet,DNS,SNMP V1,HTTP,SMTP,SNTP,ARP,PPP,SLIP
Driver support: Windows Real COM driver(Windows NT/2000, Windows XP/2003)
Configuration options: Windows, TELNET and WEB
Power
Power input: 9-24VDC
Consumption: <1W
Environment
Working temperature:-40°C~80°C
Storage temperature:-45°C~85°C
Humidity: Relative humidity 5% to 95%
Appearance
Color: Black
115*83*27mm(L*W*H)
Material: Iron (Enclosure)
World’s lowest power consumption
Safety: EN 60950-1
EMC: CE, FCC
GB/T 17626.2-2006 Class 4
GB/T 17626.4-2008 Class 4
GB/T 17626.5-2008 Class 4
GB/T 17626.6-2008 Class 3
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 55024
Power Line Protection:
EN 61000-4-4(EFT) Level 2,
EN 61000-4-5(Surge) Level 3
Warranty: 5 Years
Specifications
LAN
Ethernet 10/100 Mbps, RJ45, Auto MDI/MDIX
Protection Built-in 1.5 KV magnetic isolation
Serial Interface
Interface RS-485/422
No. Of Ports 1 port
Connector Type dB9 (male)
Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-, GND
RS-485 (4-wire) Tx+, Tx-, Rx+, Rx-, GND
Serial Line Protection: 15 KV ESD for all signals
Serial Communication Parameters
Parity None, Even, Odd, Space, Mark
Data Bits 7, 8
Stop Bits 1, 2
Flow Control RTS/CTS, XON/XOFF
Transmission Speed 50 bps to 250Kbps
Software Features
Operation Mode: RTU Slave, RTU Master, ASCII Slave, ASCII Master
Utilities: MGate Manager
Multi-Masters and: 16 simultaneous TCP masters, 32 simultaneous requests for each TCP
Multi-Request: Master
Power Requirements
Power Input 7to 35VDC
Operating Temperature: 0 to 55 C
Storage Temperature: -20 to 85 C
Safety: EN 60950-1
EMC: CE, FCC
GB/T 17626.2-2006 Class 4
GB/T 17626.4-2008 Class 4
GB/T 17626.5-2008 Class 4
GB/T 17626.6-2008 Class 3
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 55024
Power Line Protection:
EN 61000-4-4(EFT) Level 2,
EN 61000-4-5(Surge) Level 3
Warranty: 5 Years
Specifications
LAN
Ethernet 10/100 Mbps, RJ45, Auto MDI/MDIX
Protection Built-in 1.5 KV magnetic isolation
Serial Interface
Interface RS-232
No. Of Ports 1 port
Connector Type dB9 (male)
Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485 (2-wire): Data+, Data-, GND
RS-485 (4-wire) Tx+, Tx-, Rx+, Rx-, GND
Serial Line Protection: 15 KV ESD for all signals
Serial Communication Parameters
Parity None, Even, Odd, Space, Mark
Data Bits 7, 8
Stop Bits 1, 2
Flow Control RTS/CTS, XON/XOFF
Transmission Speed 50 bps to 250Kbps
Software Features
Operation Mode: RTU Slave, RTU Master, ASCII Slave, ASCII Master
Utilities: MGate Manager
Multi-Masters and: 16 simultaneous TCP masters, 32 simultaneous requests for each TCP
Multi-Request: Master
Power Requirements
Power Input 7to 35VDC
Operating Temperature: 0 to 55 C
Storage Temperature: -20 to 85 C
Safety: EN 60950-1
EMC: CE, FCC
GB/T 17626.2-2006 Class 4
GB/T 17626.4-2008 Class 4
GB/T 17626.5-2008 Class 4
GB/T 17626.6-2008 Class 3
EMI: EN 55022 Class A, FCC Part 15 Subpart B Class A
EMS: EN 55024
Power Line Protection:
EN 61000-4-4(EFT) Level 2,
EN 61000-4-5(Surge) Level 3
Warranty: 5 Years
10/100M Ethernet to Fiber Optic Converter
The HFB Series 10/100M Auto-Sensing Ethernet Fiber Optic Transceiver is designed using advanced fiber optic technology. This series transmit and receive 10/100 Mbps (no adjustment is required) data over two single-mode optical fibers, extending the Ethernet transmission distance from its normal few hundred meters to 0-120 kilometers. By using optical fiber as transmission media, this series continue to perform its secured, high-speed and long-distance communication even under the adverse condition such as lighting, power surge and electromagnetic interference; Substantial saving on lighting and power surge protection equipments if copper wires were used.
The HFB Series is fully assembled using SMT components for stability and reliability.
|
ETHERNET |
|
|
Supporting standards |
IEEE802.3 10Base-T, 100Base-T |
|
Data Rate |
10/100Mbps auto-sensing, Full Duplex or Half Duplex |
|
Physical Interface |
RJ45, DCE interface |
|
OPTICAL |
|
|
Number of Fibers |
2 |
|
Wavelength |
1310nm or 850nm |
|
Fiber Type |
9/125μ m(SM) |
|
Distance |
0 ~ 25km, 0~40km, 0~60km, 0-80km |
|
Connector Type |
ST/FC/SC |
|
GENERAL |
|
|
Operating Temperature |
-40 ~ 70C / -40 ~ +158F |
|
Relative Humidity |
0 ~ 95% non-condensing |
|
Mean Time Between Failure (MTBF) |
> 600, 000hrs |
|
Power Supply Adaptors |
AC 220V 110v or DC+110V, +5V, +12V, +24V, +48V Option |
|
Enclosure Color |
Silver |
|
Dimensions ( L× W× H ) |
25(L)× 110(W)× 36(H)Wall Mount & DIN Rail |
Ordering information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-100M-P1M |
Point to point Link,Single Fiber(BI-DI), 2km |
1 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-100M-P2M |
Point to point Link,Dual Fiber, 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-100M-P1S |
Point to point Link,Single Fiber(BI-DI), 20km |
1 |
Single Mode |
ST/SC/FC |
|
HFB-FO-100M-P2S |
Point to point Link,Dual Fiber, 20km |
2 |
Single Mode |
ST/SC/FC |
The Lonworks Multi-drop bus Fiber Optic Converter(Modem) is a multi-master and high performance Field bus Control System (FCS). Our Fiber Optic Modem uses the fiber cable as its transmission medium and utilizes Optical Fiber modulation/demodulation technology to changes the electric medium into a light medium transmission.
The Lonworks Multi-drop bus Fiber Optic Converter(Modem) product eliminates many of the disadvantages of copper cable. Examples of these disadvantages are EMI/RFI, ground loops (electrical isolation with fiber), high attenuation (high signal loss), short transmission distance between nodes of a system, and potential lightning damage.
The Lonworks Multi-drop Bus Fiber Optic Converter(Modem) can be widely used, such as Industrial Controls, Intelligent Transportation Systems (ITS), Industrial Networking, Supervisory Control and Data (SCADA) and so on.
Parameters:
| Data | |
| Data Formats | LONWORKS(LonTalk) |
| lLONWORKS Data Rate | 78kbps |
| Bit Error Rate | < 1 x 10-12 |
| Connectors | |
| Data | Screw Block Terminal |
| Fiber | ST, SC or FC (ST fitted as standard) |
| Environmental | |
| Operating Temperat ure | - 3 0 C--- +70 C |
| Storage Temperature | - 40 C--- +90 C |
| Operating Humidity | 0- 95% |
| MTBF | > 100, 000 Hours |
| Optical | |
| Fiber | Multi mode or Single mode |
| Wavelength | MM: 850nm, SM: 1310nm |
| Number of fibers | 2 or 1 |
| POWER | |
| Power Input | AC 220V 110v or DC+110V +5V +12V +24V +48V Option |
| Mechanical | |
| Dimensions | 125(L)× 110(W)× 36(H )Wall Mount & DIN Rail |
Ordering information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-LON-M2M |
Multi point Bus Link,Dual Fiber(BI-DI), 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-M4M |
Multi point Bus Link,4 Fiber, 2km |
4 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-M2S |
Multi point Bus Link,Dual Fiber(BI-DI), 20km |
2 |
Single Mode |
ST/SC/FC |
|
HFB-FO-LON-M4S |
Multi point Bus Link,4 Fiber, 20km |
4 |
Single Mode |
ST/SC/FC |
The Lonworks Fiber Optic Converter is a multi-master and high performance Field bus Control System (FCS). Our Fiber Optic Modem uses the fiber cable as its transmission medium and utilizes Optical Fiber modulation/demodulation technology to changes the electric medium into a light medium transmission.It's based on advanced technology and the outcome of great R & D team of BE.
The Lonworks Fiber Optic Converter product eliminates many of the disadvantages of copper cable. Examples of these disadvantages are EMI/RFI, ground loops (electrical isolation with fiber), high attenuation (high signal loss), short transmission distance between nodes of a system, and potential lightning damage.
The Lonworks Fiber Optic Converter can be widely used, such as Building Automation System(BAS), Industrial Controls, Intelligent Transportation Systems (ITS), Industrial Networking, Supervisory Control and Data (SCADA) and so on
Technical Parameters:
| Data | |
| Data Formats | LONWORKS(LonTalk) |
| lLONWORKS Data Rate | 78kbps FTT-10A |
| Bit Error Rate | < 1 x 10-12 |
| Connectors | |
| Data | Screw Block Terminal |
| Fiber | ST, SC or FC (ST fitted as standard) |
| Environmental | |
| Operating Temperat ure | - 3 0 C--- +70 C |
| Storage Temperature | - 40 C--- +90 C |
| Operating Humidity | 0- 95% |
| MTBF | > 100, 000 Hours |
| Optical | |
| Fiber | Multi mode or Single mode |
| Wavelength | MM: 850/1310nm, SM: 1310/1550nm |
| Number of fibers | 2 or 1 |
| POWER | |
| Power Input | AC 220V 110v or DC+110V +5V +12V +24V +48V Option |
| Mechanical | |
| Dimensions | 125(L)× 110(W)× 36(H )Wall Mount & DIN Rail |
Ordering information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-LON-P1M |
Point to point Link,Single Fiber(BI-DI), 2km |
1 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-P2M |
Point to point Link,Dual Fiber, 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-P1S |
Point to point Link,Single Fiber(BI-DI), 20km |
1 |
Single Mode |
ST/SC/FC |
|
HFB-FO-LON-P2S |
Point to point Link,Dual Fiber, 20km |
2 |
Single Mode |
ST/SC/FC |
|
HFB-FO-LON-M2M |
Multi point Bus Link,Dual Fiber(BI-DI), 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-M4M |
Multi point Bus Link,4 Fiber, 2km |
4 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-M2S |
Multi point Bus Link,Dual Fiber(BI-DI), 20km |
2 |
Single Mode |
ST/SC/FC |
|
HFB-FO-LON-M4S |
Multi point Bus Link,4 Fiber, 20km |
4 |
Single Mode |
ST/SC/FC |
|
HFB-FO-LON-R4M |
Self-healing Ring Link,4 Fiber, 2km |
4 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-LON-R4S |
Self-healing Ring Link,4 Fiber, 20km |
4 |
Single Mode |
ST/SC/FC |
CAN Bus to fiber optic Converter (CAN Bus Point-to-Point Fiber Modem)
CAN-Fiber Converter Descriptions:
The CAN Bus series products provide an optical point-to-point or bus network connection for CAN bus data interfaces on one or two, multimode or singlemode optical fibers. The CAN Bus Point-to-Point Transmission units operate as the end or terminal points and provide an electrical connection and a two fibre optical connection. The units support CAN 1.0 and CAN 2.0 CAN standards, and Device Net. And are transparent to all high level protocols.
This series is available in either wall mount, DIN rail or 3U chassis card configurations.
The HFB-FO-CAN converter can be used in fire alarm system,radar system,security,industrial automation,solar plants and other industrial fields.
Product Features
Up to 1Mbps data rate
Multimode and singlemode
Single fiber solution
Wall mount, rack or chassis configurations
| Data | |
| Data Formats | ISO-11898, CAN1.0 ,CAN2.0 , Device Net |
| CAN Data Rate | 0~1Mbps |
| Bit Error Rate | <1 x 10-12 |
| Connectors | |
| Data | Screw Block Terminal |
| Fiber | ST, SC or FC (ST fitted as standard) |
| Environmental | |
| Operating Temperat ure | - 3 0 C--- +70 C |
| Storage Temperature | - 40 C--- +85 C |
| Operating Humidity | 0- 95% |
| MTBF | >100,000 Hours |
| Optical | |
| Fiber | Multi mode or single mode |
| Wavelength | MM: 850nm, SM: 1310nm |
| Number of fibers | 2 or 1 |
| POWER | |
| Power Input | AC 220V 110v or DC+110V +5V +12V +24V +48V Option |
| Mechanical | |
| Dimensions | 125(L)×110(W)×36(H )Wall Mount & DIN Rail |
Ordering Information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-CAN-P1M |
Point to point Link,Single Fiber(BI-DI), 2km |
1 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-CAN-P2M |
Point to point Link,Dual Fiber, 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-CAN-P1S |
Point to point Link,Single Fiber(BI-DI), 20km |
1 |
Single Mode |
ST/SC/FC |
|
HFB-FO-CAN-P2S |
Point to point Link,Dual Fiber, 20km |
2 |
Single Mode |
ST/SC/FC |
Description
The HFB-FO-485 Multi-Drop Self-Healing Ring Transmission series products provide an optical self-healing ring network for RS232, RS422 /RS485 data interfaces over two multimode or singlemode optical fibers. The system offers maximum reliability as it can recover simultaneous faults or failures in two different locations and has contact closure outputs on each module to clearly indicate any fault location. The self-healing ring consists of two opposing data paths, ring A and ring B. Under normal operation only the primary path (ring A) is used for data transfer. If a fault is detected, the data is transferred to the secondary path (ring B) without interruption to the communications network.
The series is available in wall mount, DIN rail or 3U chassis card.
Product Features
Supports RS232, RS422 and RS485
Multimode and singlemode solutions
Contact closure alarm outputs per station
Single or dual fibre configurations
Wall mount, DIN rail and 3U chassis card
Typical System Configuration:

Specifications:
| Data | |
| Data Formats | RS232,RS422,RS485 |
| RS232 Data Rate | 115.2kbps |
| RS422 / 485 Data Rate | 512 kbps or 1Mkbps |
| Bit Error Rate | <1 x 10-12 |
| Connectors | |
| Data | Screw Block Terminal |
| Fiber | ST, SC or FC (ST fitted as standard) |
| Environmental | |
| Operating Temperat ure | - 3 0 C--- +70 C |
| Storage Temperature | - 40 C--- +85C |
| Operating Humidity | 0- 95% |
| MTBF | >100,000 Hours |
| Optical | |
| Fiber | Multi mode or single mode |
| Wavelength | MM: 850/1310nm, SM: 1310/1550nm |
| Number of fibers | 4 or 2 |
| POWER | |
| Power Input | AC 220V 110v or DC+110V +5V +12V +24V +48V Option |
| Mechanical | |
| Dimensions | 125(L)×110(W)×36(H )Wall Mount & DIN Rail |
Ordering Information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-485-R2M |
Redundant Ring Link,Dual Fiber(BI-DI), 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-485-R4M |
Redundant Ring Link,4 Fiber, 2km |
4 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-485-R2S |
Redundant Ring,Dual Fiber(BI-DI), 20km |
2 |
Single Mode |
ST/SC/FC |
|
HFB-FO-485-R4S |
Redundant Ring,4 Fiber, 20km |
4 |
Single Mode |
ST/SC/FC |
RS-485 Multi-Drop Bus Fiber Optic converter
The RS-485/422 Multi-Drop Bus Fiber Optic Modem series products provide an optical bus network for RS-232, RS-422 or RS-485 data interfaces over a pair of multimode or singlemode optical fibers. The Terminal module units operate as the end or terminal points and provide an electrical connection and a two fibre optical connection. The Repeater module units act as in-line repeater stations and provide a single electrical connection and two optical connections, one upstream and one downstream.
This series is available in either wall mount, DIN rail or 3U chassis card configurations.
Product Features
Multi protocol data interface
Switchable termination and biasing
Multimode and singlemode
Wall mount, DIN and 3U chassis card
Parameters:
| Data | |
| Data Formats | RS232,RS422,RS485 |
| RS232 Data Rate | 115.2kbps |
| RS422 / 485 Data Rate | 512 kbps or 1Mkbps |
| Bit Error Rate | <1 x 10-12 |
| Connectors | |
| Data | Screw Block Terminal |
| Fiber | ST, SC or FC (ST fitted as standard) |
| Environmental | |
| Operating Temperat ure | - 3 0 C--- +70 C |
| Storage Temperature | - 40 C--- +85 C |
| Operating Humidity | 0- 95% |
| MTBF | >100,000 Hours |
| Optical | |
| Fiber | Multimode or singlemode |
| Wavelength | MM: 850/1310nm, SM: 1310/1550nm |
| Number of fibers | 4 or 2 |
| POWER | |
| Power Input | AC 220V 110v or DC+110V +5V +12V +24V +48V Option |
| Mechanical | |
| Dimensions | 125(L)×110(W)×36(H )Wall Mount & DIN Rail |
Ordering Information:
|
Model Number |
Description |
Fiber No. |
Fiber Mode |
Fiber Connector |
|
HFB-FO-485-M2M |
Multi point Link,Dual Fiber(BI-DI), 2km |
2 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-485-M4M |
Multi point Link,4 Fiber, 2km |
4 |
Multi Mode |
ST/SC/FC |
|
HFB-FO-485-M2S |
Multi point Link,Dual Fiber(BI-DI), 20km |
2 |
Single Mode |
ST/SC/FC |
|
HFB-FO-485-M4S |
Multi point Link,4 Fiber, 20km |
4 |
Single Mode |