Overview:
* High Port Density, Up to 24 Fast-Ethernet Ports and 2 Gigabit Combo Ports
* Elastic configuration, 100Base fiber port with SC/ST connectors, multi-mode/single-mode models are available
* Multiple power inputs include low voltage redundant power models or 110/220VAC models
Specifications
* Technology
Network Standards:
IEEE802.3 10Base-T
IEEE802.3u 100BaseT(X) and 100BaseFX
IEEE802.3ad 1000Base(X)
IEEE802.3z 1000BaseSX/LX/HLX/ZX
IEEE802.3x Flow Control
Flow Control:Full/Half Duplex Back Pressure Flow Control
* Interface
RJ45 Port Connectors:10/100Base(X) or 10/100/1000BaseT(X) Auto-Negotiation
Fiber Port Connectors:1000BaseSX/CX/LHX/ZX(SFP slots, LC connectors)
LED Indicators:Power, Port Status, 10/100/1000M
* Power Requirements
Power Inputs:48VDC(8~56VDC); 110/220VAC(85~265VDC);
220VDC(120~370VDC); 110VDC(100~120VDC);
* Fiber Optic:
|
Mode |
Typical Dist |
Wavelength |
Cable Size |
TX Power |
Rx Sensitivity |
Transmission speed |
|
Multi |
2km |
1310nm |
62.5/125um |
-23.5~-14dBm |
< -35dBm |
10/100/1000Mbps |
|
Single |
15km |
1310nm |
9/125um |
-15~-8dBm |
< -35dBm |
10/100/1000Mbps |
* Physical Characteristics
Case:Slim Metal Case, IP40 Design
Dimensions:(W×H×D):443×44×220mm(HFB18C-2G/26C-2G)
Installation:19" rack mounting
* Environment Limits
Standard Temp Models:-10˚C to 60˚C
Extended Temp Models:-40˚C to 75˚C
Storage Temperature:-40 to 85℃
Ambient Relative Humidity: 10 to 95%(Non-condensing)
* Ordering Information
|
Product Model |
Connectors |
||||
|
(-10℃~60℃) |
(-40℃~75℃) |
10/100/ |
10/100 |
100BaseFX |
|
|
MM Fiber, SC |
SM Fiber, SC |
||||
|
HFB18C-2G Series |
|||||
|
HFB18C-2G |
HFB18C-2G-W |
2 |
16 |
|
|
|
HFB18C-2G-2SC |
HFB18C-2G-2SC-W |
2 |
14 |
2 |
|
|
HFB18C-2G-2SSC |
HFB18C-2G-2SSC-W |
2 |
14 |
|
2 |
|
HFB18C-2G-4SC |
HFB18C-2G-4SC-W |
2 |
12 |
4 |
|
|
HFB18C-2G-4SSC |
HFB18C-2G-4SSC-W |
2 |
12 |
|
4 |
|
HFB26C-2G Series |
|||||
|
HFB26C-2G |
HFB26C-2G-W |
2 |
24 |
|
|
|
HFB26C-2G-2SC |
HFB26C-2G-2SC-W |
2 |
22 |
2 |
|
|
HFB26C-2G-2SSC |
HFB26C-2G-2SSC-W |
2 |
22 |
|
2 |
|
HFB26C-2G-4SC |
HFB26C-2G-4SC-W |
2 |
20 |
4 |
|
|
HFB26C-2G-4SSC |
HFB26C-2G-4SSC-W |
2 |
20 |
|
4 |
* Up to 24 Fast-Ethernet Ports and 2 Gigabit Combo Ports
* RingOn™ Redundant Ring Technology, Recovery Time
within 15ms, Supports RSTP/STP
* Enriched Management Features: QoS, IGMP snooping/
GMRP, VLAN, SNMP V1/V2/V3
* Multiple Redundant AC/DC Power Choices
Specifications
* Technology
Network Standards:
IEEE802.3 10Base-T
IEEE802.3u 100BaseT(X) and 100BaseFX
IEEE802.3ad 1000Base(X)
IEEE802.3z 1000BaseSX/LX/HLX/ZX
IEEE802.3x Flow Control
IEEE802.1p Classe of Service
IEEE802.1Q VLAN Tagging
IEEE802.1ad LACP
IEEE802.1D for Spanning Tree Protocol
IEEE802.1W for Rapid STP
IEEE802.1X for Authentication
Flow Control:Full/Half Duplex Back Pressure Flow Control
Protocols:SNMP V1/V2/V3, DHCP Server, SNTP, SMTP, IGMP Snooping/GMRP, LACP, RMON,
HTTPS, Telnet, Syslog, HTTP
* Switch Properties
Priority Queues:4
IGMP Groups:64
Max. Available VLANs:256
VLAN ID Range:1~4096
* Interface
RJ45 Port Connectors:10/100Base(X) or 10/100/1000BaseT(X) Auto-Negotiation
Fiber Port Connectors:1000BaseSX/CX/LHX/ZX(SFP slots, LC connectors)
LED Indicators:Power, Port Status, 10/100/1000M
Console Port:DB9 male
Output Warning:Relay, Standard 2 Pin, 0.5A@24VDC
* Power Requirements
Power Inputs:48VDC(8~56VDC); 110/220VAC(85~265VDC);
220VDC(120~370VDC); 110VDC(100~120VDC);
* Fiber Optic
|
Mode |
Typical Dist |
Wavelength |
Cable Size |
TX Power |
Rx Sensitivity |
Transmission speed |
|
Multi |
2km |
1310nm |
62.5/125um |
-23.5~-14dBm |
< -35dBm |
10/100/1000Mbps |
|
Single |
15km |
1310nm |
9/125um |
-15~-8dBm |
< -35dBm |
10/100/1000Mbps |
* Physical Characteristics
Case:Slim Metal Case, IP40 Design
Dimensions:(W×H×D):443×44×220mm(HFB18MC-2G/26MC-2G)
Installation:19" rack mounting
* Environment Limits
Standard Temp Models:-10˚C to 60˚C
Extended Temp Models:-40˚C to 75˚C
Storage Temperature:-40 to 85℃
Ambient Relative Humidity: 10 to 95%(Non-condensing)
* Ordering Information
|
Product Model |
Connectors |
|||||
|
Standard Temperature(-10℃~60℃) |
Extended |
10/100/ |
10/100 |
100BaseFX |
||
|
MM Fiber, SC |
SM Fiber, SC |
|||||
|
HFB18MC-2G Series |
||||||
|
HFB18MC-2G |
HFB18MC-2G-W |
2 |
16 |
|
|
|
|
HFB18MC-2G-2SC |
HFB18MC-2G-2SC-W |
2 |
14 |
2 |
|
|
|
HFB18MC-2G-2SSC |
HFB18MC-2G-2SSC-W |
2 |
14 |
|
2 |
|
|
HFB18MC-2G-4SC |
HFB18MC-2G-4SC-W |
2 |
12 |
4 |
|
|
|
HFB18MC-2G-4SSC |
HFB18MC-2G-4SSC-W |
2 |
12 |
|
4 |
|
|
HFB26MC-2G Series |
||||||
|
HFB26MC-2G |
HFB26MC-2G-W |
2 |
24 |
|
|
|
|
HFB26MC-2G-2SC |
HFB26MC-2G-2SC-W |
2 |
22 |
2 |
|
|
|
HFB26MC-2G-2SSC |
HFB26MC-2G-2SSC-W |
2 |
22 |
|
2 |
|
|
HFB26MC-2G-4SC |
HFB26MC-2G-4SC-W |
2 |
20 |
4 |
|
|
|
HFB26MC-2G-4SSC |
HFB26MC-2G-4SSC-W |
2 |
20 |
|
4 |
|
Supports up to 8 Fiber optic Ports, Increase Flexibility,Ruggedized Industrial Grade Housing,Multiple power inputs include low voltage redundant power models and 220VAC models,Broadcasting Storm Controller
Specifications:
Technology
Network Standards:
IEEE802.3 10Base-T
IEEE802.3u 100BaseT(X) and 100BaseFX
IEEE802.3x Flow Control
MAC Address:8K MAC Address Table
Flow Control:Full/Half Duplex Back Pressure Flow Control
Interface
RJ45 Port Connectors:10/100Base Auto-sensing, Full/Half Duplex MDI/MDI-X Auto-Negotiation
Fiber Port Connectors:100BaseFX, SC or ST connectors, Single-Mode or Multi-Mode
LED Indicators:Power, Port Status
Power Requirements
Power Inputs:48VDC(8~56VDC); 110/220VAC(85~265VDC);
220VDC(120~370VDC); 110VDC(100~120VDC);
Optical Fiber
|
Mode |
Typical Dist |
Wavelength |
Cable Size |
TX Power |
Rx Sensitivity |
Transmission speed |
|
Multi |
2km |
1310nm |
62.5/125um |
-23.5~-14dBm |
< -35dBm |
10/100Mbps |
|
Single |
15km |
1310nm |
9/125um |
-15~-8dBm |
< -35dBm |
10/100Mbps |
Physical Characteristics
Case:Slim Metal Case, IP30 Design
Dimensions:(W×H×D):443×44×220mm(HFB8C/18C/26C)
Installation:19" rack mounting
Environment Limits
Standard Temp Models:-10˚C to 60˚C
Extended Temp Models:-40˚C to 75˚C
Storage Temperature:-40 to 85℃
Ambient Relative Humidity: 10 to 95%(Non-condensing)
Ordering Information
|
Product Model |
Connectors |
||||
|
Standard Temp(-10℃~60℃) |
Extended Temp(-40℃~75℃) |
10/100BaseT(X) |
100BaseFX |
||
|
MM Fiber, SC |
SM Fiber, SC |
||||
|
HFB8C Series |
|||||
|
HFB8C |
HFB8C-W |
8 |
|
|
|
|
HFB8C-2SC |
HFB8C-2SC-W |
6 |
2 |
|
|
|
HFB8C-2SSC |
HFB8C-2SSC-W |
6 |
|
2 |
|
|
HFB8C-4SC |
HFB8C-4SC-W |
4 |
4 |
|
|
|
HFB8C-4SSC |
HFB8C-4SSC-W |
4 |
|
4 |
|
|
HFB8C-8SC |
HFB8C-8SC-W |
|
8 |
|
|
|
HFB8C-8SSC |
HFB8C-8SSC-W |
|
|
8 |
|
|
HFB18C Series |
|||||
|
HFB18C |
HFB18C-W |
18 |
|
|
|
|
HFB18C-2SC |
HFB18C-2SC-W |
16 |
2 |
|
|
|
HFB18C-2SSC |
HFB18C-2SSC-W |
16 |
|
2 |
|
|
HFB18C-4SC |
HFB18C-4SC-W |
14 |
4 |
|
|
|
HFB18C-4SSC |
HFB18C-4SSC-W |
14 |
|
4 |
|
|
HFB26C Series |
|||||
|
HFB26C |
HFB26C-W |
26 |
|
|
|
|
HFB26C-2SC |
HFB26C-2SC-W |
24 |
2 |
|
|
|
HFB26C-2SSC |
HFB26C-2SSC-W |
24 |
|
2 |
|
|
HFB26C-4SC |
HFB26C-4SC-W |
22 |
4 |
|
|
|
HFB26C-4SSC |
HFB26C-4SSC-W |
22 |
|
4 |
|
|
HFB26C-6SC |
HFB26C-6SC-W |
20 |
6 |
|
|
|
HFB26C-6SSC |
HFB26C-6SSC-W |
20 |
|
6 |
|
RingOn™ Redundant Ring Technology, Recovery Time within 15ms, Supports RSTP/STPEnriched Management Features: QoS, IGMP snooping/GMRP, VLAN, SNMP V1/V2/V3Multiple power inputs include low voltage redundantUpgrated EMI Immunity
Specifications
* Technology Network Standards:
IEEE802.3 10Base-T
IEEE802.3u 100BaseT(X), 100BaseFX
IEEE802.3x Flow Control
IEEE802.1p Classe of Service
IEEE802.1Q VLAN Tagging
IEEE802.1ad
LACP Processing Type:Store and Forward MAC Address:8k MAC
Address Table Management:by Web Browse RingOn™:Recovery Time within 15ms
Broadcasting Storm Control:Automatic
Flow Control:Full/Half Duplex
Back Pressure Flow Control Protocols:SNMP V1/V2/V3, DHCP Server, SNTP, SMTP, IGMP Snooping/GMRP, LACP, RMON, HTTPS, Telnet, Syslog, HTTP
* Switch Properties Priority Queues:4 IGMP Groups:64 Max.
Available VLANs:256 VLAN ID Range:1~4096
* Interface RJ45 Port Connectors:10/100Base Auto-sensing, Full/Half Duplex MDI/MDI-X Auto-Negotiation
Fiber Port Connectors:100BaseFX, SC or ST connectors, Single-Mode or Multi-Mode
LED Indicators:Power, Port Status Console Port:DB9 male Output Warning:Relay, Standard 2 Pin, 0.5A@24VDC
* Power Requirements: Power Inputs:48VDC(8~56VDC); 110/220VAC(85~265VDC); 220VDC(120~370VDC); 110VDC(100~120VDC);
* Optical Fiber
Mode Typical Distance Wavelength Cable Size TX Power Rx Sensitivity Transmission speed
Multi 2km 1310nm 62.5/125um -23.5~-14dBm < -35dBm 10/100Mbps
Single 15km 1310nm 9/125um -15~-8dBm < -35dBm 10/100Mbps
* Physical Characteristics Case:Slim Metal Case, IP30 Design Dimensions:(W×H×D):443×44×220mm(HFB18MC/26MC) Installation:19" rack mounting* Environment Limits Standard
Temp Models:-10˚C to 60˚C
Extended Temp Models:-40˚C to 75˚C
Storage Temperature:-40 to 85℃
Ambient Relative Humidity: 10 to 95%(Non-condensing)
* Ordering Information
|
Product Model |
Connectors |
|||
|
Standard Temp(-10℃~60℃) |
Extended Temp(-40℃~75℃) |
10/100BaseT(X) |
100BaseFX |
|
|
|
|
|
MM Fiber/SC |
SM Fiber/SC |
|
HFB18MC Series |
||||
|
HFB18MC |
HFB18MC-W |
18 |
|
|
|
HFB18MC-2SC |
HFB18MC-2SC-W |
16 |
2 |
|
|
HFB18MC-2SSC |
HFB18MC-2SSC-W |
16 |
|
2 |
|
HFB18MC-4SC |
HFB18MC-4SC-W |
14 |
4 |
|
|
HFB18MC-4SSC |
HFB18MC-4SSC-W |
14 |
|
4 |
|
HFB26MC Series |
||||
|
HFB26MC |
HFB26MC-W |
26 |
|
|
|
HFB26MC-2SC |
HFB26MC-2SC-W |
24 |
2 |
|
|
HFB26MC-2SSC |
HFB26MC-2SSC-W |
24 |
|
2 |
|
HFB26MC-4SC |
HFB26MC-4SC-W |
22 |
4 |
|
|
HFB26MC-4SSC |
HFB26MC-4SSC-W |
22 |
|
4 |
|
HFB26MC-6SC |
HFB26MC-6SC-W |
20 |
6 |
|
|
HFB26MC-6SSC |
HFB26MC-6SSC-W |
20 |
|
6 |